Iron and manganese removal filters


IRON, MANGANESE AND HYDROGEN SULFIDE REMOVAL FILTER SYSTEMS

They can be removed from the water using a filter medium that promotes the reaction between the contaminants and the oxygen present in the water. This reaction forms an insoluble precipitate which can be further filtered by the filter medium. The medium acts as a catalyst, which means that although it promotes the reaction it is not consumed in the process, allowing the filter medium a long life.The iron and manganese dissolved in the water are responsible for staining sanitary ware, clothing and other surfaces in which it contacts , becoming a drawback to the user.

Conditions of use:
  • Maximum iron concentration: 5 mg / l
  • Maximum concentration of manganese: 1 mg / l
  • Minimal dissolved oxygen: 20% of Fe + Mn concentration
  • Recommended pH: 7 for iron and 7,8 for manganese
  • Maximum free chlorine: 0,5 mg / l

 Models

Automatic filters Autotrol

  • Meio desferrizante: Aquamandix, Birm, Greensand
  • Vessel body made in polyester reinforced fiberglass.
  • Automatic cleaning valve for time Autotrol/ Logix 742F, 1″ and 2″ , which controls the operating and backwashing stages.
Vessel size

Valve model

Connections

Load

(Lts)

Filtration area

(m2)

Maximum

Flow rate

 (m3/h)

Backwashing flow rate

(m3/h)

Height

(mm)

Diametro

(mm)

(10 m/h)(15 m/h)
10 x 54263-742F1”450,050,50,81,51608257
13 x 54263- 742F1”700,080,91,32,41608334
14 x 65263- 742F1”1000,1011,53,01861363
16 x 65263- 742F1”1250,131,32,03,91925420
18 x 65263- 742F1”1260,161,82,74,81925490
21 x 62Magnum-742F2″1850,222,23,26,61860550
24 x 72Magnum-742F2″2850,292,94,48,72100630
30 x 72Magnum-742F2″4250,454,56,813,52325780

Automatic filters Siata S363

  • S363 automatic valve in ABS
  • Programmer SFE of chronometric control, with programmable regeneration adjustment of 1 to 7 days.
  • Connections 2 “F
    Working pressure: 2.5 to 6 bar
  • Operating temperature: 0-35ºC
  • Power supply 220 V-12 V, 50 Hz
  • Cutting of water passage during regeneration.

Vessel size

Valve modelConnectionsAquamandix

Load

(Lts)

Filtration area

(m2)

Maximum

Flow rate

 (m3/h)

Backwashing flow rate

(m3/h)

Height

(mm)

Diametro

(mm)

30×72

S363/SFE2″4300,454,511,52.400780

36×72

S363/SFE2″6000,656,516,32.410

931

42×72

S363/SFE2″8500,80820,02.425

1.090

48×72S363/SFE2″12001,1611,629,02.405

1.235